Stepper Servo · 17 Years of Expertise
Product
CL86-R Bus Closed-Loop Stepper Driver
Product Overview
The CL86-R stepper driver adopts the new generation 32-bit DSP technology, combined with RS485 bus control functionality, supporting the MODBUS-RTU communication protocol. It can connect up to 32 axes and achieve multi-axis bus synchronous control. The driver features 15 internal position segments and 15 internal speed segments, supports automatic homing, absolute/relative positioning, JOG, and other functions. It can be directly controlled using a touchscreen or a controller with an RS485 interface.
Features
Main Parameter Description
(1) Product Specifications
| Matched Motor | Two-phase 60/86 Stepper Closed-loop Motor | DI Port Input Voltage | 24V DC |
| Power Supply Voltage | DC30V~1100V / AC20V~80V | Encoder | 1000-line Incremental |
| Maximum Output Current | 8A | Insulation Resistance | 100MΩ |
| DI Port Input Current | 10~50mA | Driver Dimensions | 150*97.5*52.6mm |
| Storage Environment | -20~65℃ (no frost), below 90% RH (no condensation) | Driver Weight | 0.5kg |
Operating Environment | Temperature: 0℃~45℃; Humidity: ≤90% RH without condensation; Altitude: ≤1000m; Installation environment: no corrosive gases, flammable gases, oil mist or dust; Vibration: less than 0.5G (4.9m/s²), 10~60 Hz (non-continuous operation) | ||
Product Diagram

Interface Definition
(1) Motor and Power Input Interface
Symbol | Name | Description |
A+ | A Positive end of phase motor winding | - |
A- | A Negative end of phase motor winding | - |
B+ | B Positive end of phase motor winding | - |
B- | B Negative end of phase motor winding | - |
AC | Power Input Terminal | 30V~110VDC 20V~80VAC |
AC | Power Input Terminal |
(2) Driver Encoder Terminal Definition
Symbol | Name | Symbol | Name |
EA+ | Motor Encoder Phase A Positive Input | EZ- | Motor Encoder Phase Z Negative Input |
EA- | Motor Encoder Phase A Negative Input | EVCC | Encoder Power Positive |
EB+ | Motor Encoder Phase B Positive Input | EGND | Encoder Power Negative |
EB- | Motor Encoder Phase B Negative Input | NC | No Connection Pin |
EZ+ | Motor Encoder Phase Z Positive Input | NC | No Connection Pin |
(3) DI/DO Signal Interface
Symbol | Name | Symbol | Name |
DI0 | Single-ended input; effective operating voltage 24V | DI6 | Single-ended input; effective operating voltage 24V |
DI1 | Single-ended input; effective operating voltage 24V | DICOM | Input Common Terminal; compatible with common anode/cathode wiring |
DI2 | Single-ended input; effective operating voltage 24V | DO0 | Single-ended output |
DI3 | Single-ended input; effective operating voltage 24V | DO1 | Single-ended output |
DI4 | Single-ended input; effective operating voltage 24V | DO2 | Single-ended output |
DI5 | Single-ended input; effective operating voltage 24V | DOCOM | Output Common Terminal; can only connect to power negative terminal |
Station Number Setting
| Station Number | SW1 | SW2 | SW3 | SW4 | SW5 | Station Number | SW1 | SW2 | SW3 | SW4 | SW5 |
| Custom | off | off | off | off | off | 16 | off | off | off | off | on |
| 1 | on | off | off | off | off | 17 | on | off | off | off | on |
| 2 | off | on | off | off | off | 18 | off | on | off | off | on |
| 3 | on | on | off | off | off | 19 | on | on | off | off | on |
| 4 | off | off | on | off | off | 20 | off | off | on | off | on |
| 5 | on | off | on | off | off | 21 | on | off | on | off | on |
| 6 | off | on | on | off | off | 22 | off | on | on | off | on |
| 7 | on | on | on | off | off | 23 | on | on | on | off | on |
| 8 | off | off | off | on | off | 24 | off | off | off | on | on |
| 9 | on | off | off | on | off | 25 | on | off | off | on | on |
| 10 | off | on | off | on | off | 26 | off | on | off | on | on |
| 11 | on | on | off | on | off | 27 | on | on | off | on | on |
| 12 | off | off | on | on | off | 28 | off | off | on | on | on |
| 13 | on | off | on | on | off | 29 | on | off | on | on | on |
| 14 | off | on | on | on | off | 30 | off | on | on | on | on |
| 15 | on | on | on | on | off | 31 | on | on | on | on | on |
Baud Rate Setting
| Baud Rate | 9600 | 19200 | 38400 | 115200 |
| SW6 | on | off | on | off |
| SW7 | on | on | off | off |
Terminal Resistor Setting: When SW8 is set to ON, a 120Ω terminal resistor is connected between signal lines to prevent signal reflection at the cable end when nodes send signals on the network.
Main Application Areas
Suitable for various motion control automation equipment and instruments, such as: electronic processing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, automated assembly equipment, etc.
Shenzhen Lichuan Electric Co., Ltd.
Technical Support
Engineer Peng:+86-135-3098-8140
Engineer Xie:86-159-0755-7836
Engineer Rao:86-180-2520-1553
Engineer Zuo:86-180-2901-2526
WeChat Public Account
Douyin ID
Official Website Mobile Version
English website: https://www.lichuanservomotor.com/
Sorry,当前栏目暂无内容!
您可以查看其他栏目或返回 首页
Sorry,The current column has no content!
You can view other columns or return Home
WeChat