Stepper Servo · 17 Years of Expertise

  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
+
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
OL3-E86H Bus Open-Loop Stepper Driver
+
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver
  • OL3-E86H Bus Open-Loop Stepper Driver

OL3-E86H Bus Open-Loop Stepper Driver

Product Overview

OL3-E86H bus-type stepper motor driver is a digital stepper motor driver that combines advanced digital stepper motor algorithms withtherCAT bus communication protocol. This product supports CoE (CANopen over EtherCAT) protocol and conforms to CIA402 standard. Compared with traditional pulse- drivers, bus-type drivers have simpler wiring, real-time data transmission, high reliability communication, and can achieve multi-axis synchronous communication control. This series of drivers samples digital stepper motor algorithms, which can effectively suppress the temperature rise of the motor, reduce motor vibration, and can be adapted to 42/57/60 series-loop stepper motors.

Features

Voltage input range: DC24V to 110V / AC18V to 80V Maximum peak current: 8A Communication interface: EtherCAT Communication protocol: CoE (CANopen over EtherCAT) protocol Automatic motor parameter tuning function Features overvoltage, overcurrent, and other protection functions
Product Overview Supporting Products Data Download
 
EtherCAT Communication Specifications

Physical Layer

100BASE-T

Communication Connector

RJ45 × 2 (Input: CN6A; Output: CN6B)

Network Architecture

Daisy Chain

Transmission Rate

2 x 100 Mbps (Full Duplex)

Data Frame Length

Maximum 1484 bytes

Application Layer Protocol

CoE: CANopen over EtherCAT

Synchronization Mode

DC Synchronization Mode (SYNC0); Asynchronous Mode (Free Run)

Communication Objects

SDO: Non-cyclic Data Object; PDO: Cyclic Data Object; EMCY: Emergency Object

Application Layer Specifications

CiA402 Drive Profile

Supported Control Modes

Profile Position Mode (PP); Profile Velocity Mode (PV); Homing Mode (HM); Cycle Synchronized Position Mode (CSP)

 
Product Diagram
 
Main Parameter Description

(1) Motor and Power Input Interface

Symbol

Name

Description

A+

A Positive end of phase motor winding

-

A-

A Negative end of phase motor winding

-

B+

B Positive end of phase motor winding

-

B-

B Negative end of phase motor winding

-

VDC

Positive terminal of DC power input

24V~110VDC / 18V~80VAC

GND

Negative terminal of DC power input

(2) DI/DO Signal Interface

SymbolName

DI1+

Differential input signal DI1, valid at 12V~24V, maximum input frequency 500K, signal function configurable, default function is probe input signal 1.

DI1-

DI2+

Differential input signal DI2, valid at 12V~24V, maximum input frequency 500K, signal function configurable, default function is probe input signal 2.

DI2-

DI3

Single-ended input signal, valid at 12V~24V, default is origin signal.

DI4

Single-ended input signal, valid at 12V~24V, default is positive limit signal.

DI5

Single-ended input signal, valid at 12V~24V, default is negative limit signal.

DI6

Single-ended input signal, valid at 12V~24V, no default function defined.

DICOM

Common terminal for single-ended input signals, can be connected as common anode or common cathode.

DO1+

Differential output signal DO1, maximum current 100mA, default is alarm output signal.

DO1-

DO2+

Differential output signal DO2, maximum current 100mA, default is positioning complete signal.

DO2-

DO3+

Differential output signal DO3, maximum current 100mA, default is homing complete signal.

DO3-

+24V

Brake signal 24V power positive input terminal.

BK

Brake control signal, can be connected directly to motor brake without relay.

GDS

Brake signal 24V power negative input terminal.

 
Main Application Areas

Applicable to 3C electronics industry, stage lighting control, robotic arms, medical, lithium battery and other automation equipment.

 

Category

Model

Format

Download

EtherCAT Bus Stepper Driver

Bus Driver Series

Driver Manual

Data Download

EtherCAT Bus Stepper Driver Manual

EtherCAT Bus Stepper Driver Manual

EtherCAT Bus Stepper Driver

Bus Driver Series

3D Drawing

Data Download

CL3/OL3-E86H 3D Diagram

CL3/OL3-E86H 3D Diagram
< 1 > proceed page