Stepper Servo · 17 Years of Expertise

  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
+
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
60 L-type Integrated Motor (Pulse)
+
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)
  • 60 L-type Integrated Motor (Pulse)

60 L-type Integrated Motor (Pulse)

Product Overview

This series of integrated stepper drive units adopts the new generation 32-bit DSP technology, combining the control functions of a separate driver. It supports current auto-tuning, pulse + direction control, dual pulse control, and other features. While improving motor stability without losing steps and reducing temperature rise, it also enhances high-speed motor performance, reduces motor vibration, increases machining speed and precision, and lowers machine power consumption.

Features

Voltage input range: DC24V to 50V Drive current: 5.6A Communication interface: Pulse Input pulse frequency: 0-200KHZ Baud rate: 115200 Features protection functions such as overvoltage, overcurrent, undervoltage, and position deviation [closed loop].
Product Overview Supporting Products Data Download
 
Technical Parameters

Pulse Model

Step Angle (°)

Body Length L (mm)

Holding Torque (N.m)

Phase Current (A)

Rotational Inertia (g.cm2)

Motor Weight (kg)

Encoder Line Count (PPR)

TLO60P-36V-3

1.8

119.2

3.0

4.0

560

1.45

None

TLO60P-36V-3.5

1.8

131.2

3.5

4.0

620

1.72

None

TLO60P-36V-4

1.8

143.2

4.0

4.0

1000

1.9

None

TLC60P-36V-3

1.8

119.2

3.0

4.0

560

1.45

1000

TLC60P-36V-3.5

1.8

131.2

3.5

4.0

620

1.72

1000

TLC60P-36V-4

1.8

143.2

4.0

4.0

1000

1.9

1000

 
Motor Shaft Output Description

Model (Open Loop)

Model (Closed Loop)

Shaft Diameter D (mm)

Shaft Extension (mm)

Shaft Length (mm

TLO60P-36V-3

TLC60P-36V-3

φ8

Flat 0.5×20

25

TLO60P-36V-3.5

TLC60P-36V-3.5

φ8

Flat 0.5×20

25

TLO60P-36V-4

TLC60P-36V-4

φ8

Flat 0.5×20

25

 
Electrical Parameters

TLO and TLC60 Pulse Type Integrated Machine

Category

Minimum Value

Typical Value

Maximum Value

Unit

Input Voltage

24

36

50

V

Drive Current

5.6 

A

Input Pulse Frequency

0-200K

 

Baud Rate

115200

 

Protection Functions

Overcurrent, Overvoltage, Undervoltage, Position Deviation (Closed Loop)

 
Driver Port Definition

1. RS232 Debug Port

Pin

1

2

3

4

5

Signal Definition

NC

RX

GND

TX

5V

2. DI/DO Port

Pin

Definition

Description

1

PUL+

Pulse signal input, signal voltage supports 5V-24V; pulse input modes: pulse + direction (used as pulse port), dual pulse (used as CW port); pulse active edge adjustable, default pulse rising edge active; to reliably respond to pulse signals, pulse width should be greater than 2.5μs.

2

PUL-

3

DIR+

Used as direction input port, signal voltage supports 5V-24V; pulse input modes: pulse + direction (used as direction port), dual pulse (used as CCW port); high/low level signal, to ensure reliable motor direction change, direction signal should be established at least 5μs before pulse signal.

4

DIR-

5

ENA+

Enable control signal, this input signal is used to enable or disable the output of driver axis 1 and axis 2. When ENA is connected to low level (or internal optocoupler conduction), the driver will cut off current to each motor phase, putting the motor in free state and not responding to step pulses. When this function is not needed, the enable signal terminal can be left floating. (Signal voltage supports 5-24V)

6

ENA-

7

ALM+

Alarm Output

8

ALM-

9

PEND+

In-position Output

10

PEND-

 
Driver Wiring Diagram / Dimension Drawing

 

DIP Switch Settings

This series of pulse type integrated machines has 6 DIP switches, which can be used to set microstepping, direction, and pulse input mode, distributed as shown in the figure below:

 
Single/Dual Pulse Setting

Pulse Mode  

SW5

PUL+DIR

OFF

CW/CCW

ON

Direction Setting: When the motor direction is exactly opposite to the device system direction, SW6 can be set to ON, at which point the motor direction will be reversed.

 

Driver Microstepping Setting

Microstepping

SW1

SW2

SW3

SW4

Custom

OFF

OFF

OFF

OFF

800

ON

OFF

OFF

OFF

1600

OFF

ON

OFF

OFF

3200

ON

ON

OFF

OFF

6400

OFF

OFF

ON

OFF

12800

ON

OFF

ON

OFF

25600

OFF

ON

ON

OFF

51200

ON

ON

ON

OFF

1000

OFF

OFF

OFF

ON

2000

ON

OFF

OFF

ON

4000

OFF

ON

OFF

ON

5000

ON

ON

OFF

ON

8000

OFF

OFF

ON

ON

10000

ON

OFF

ON

ON

20000

OFF

ON

ON

ON

40000

ON

ON

ON

ON

 

Main Application Areas

Suitable for various motion control automation equipment and instruments, such as electronic processing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, automated assembly equipment, etc. It is the preferred choice for users seeking low noise, superior high-speed performance, and competitive cost-effectiveness.

 