Stepper Servo · 17 Years of Expertise

  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
+
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
42 Backpack-type Integrated Motor (Pulse)
+
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)
  • 42 Backpack-type Integrated Motor (Pulse)

42 Backpack-type Integrated Motor (Pulse)

Product Overview

The LC42BK-P integrated stepper driver features a revolutionary design, with a core advantage of ultra-compact structure, integrated wiring port layout, saving equipment space and reducing wiring complexity. Built-in high-precision encoder (resolution 16384PPR), combined with closed-loop feedback algorithm, positioning can reach ±0.02°, effectively eliminating the risk of missing steps, suitable for high-precision positioning scenarios. This driver supports two control modes: pulse mode and IO, which can be switched through software settings, flexibly adapting to different working occasions.

Features

Power supply voltage: DC24V~50V Output peak current: 3.0A Communication interface: Pulse Pulse input frequency: 200KHZ Communication protocol: Modbus RTU With overcurrent, overvoltage, excessive deviation and other alarm protection functions
Product Overview Supporting Products Data Download
 
Product Specifications
Item
Description
Power Supply Voltage
DC24V~50V
Power Supply Power
Single Motor Power ≥ 100W
Output Peak Current
3A
Encoder Resolution
16384ppr (No encoder for open-loop model)
Pulse Input Frequency
200KHz
Pulse Mode
PUL+DIR and CW+CCW
Communication Interface
COM: Serial port, requires dedicated serial cable for communication; R485: Not supported by default, customization required
Communication Protocol
Modbus RTU
Storage Temperature
-20℃~65℃
Protection Measures
Overcurrent, overvoltage, large deviation alarm protection functions
Operating Temperature
0℃~50℃
Operating Humidity
40~90%RH (non-condensing)
Vibration Frequency
Less than 0.5G (4.9m/s²) 10Hz~55Hz (non-continuous operation)
Operating Environment
Avoid dust, oil stains, corrosive gases, excessive humidity and strong vibration; combustible gases and conductive dust are prohibited
 
Technical Parameters

Pulse Model

Step Angle (°)

Body Length L (mm)

Holding Torque (N.m)

Phase Current (A)

Rotational Inertia (g.cm²)

Motor Weight (kg)

Encoder Line Count (PPR)

LC42BK-P-48N048

1.8

69

0.48

1.2

68

0.38

None

LC42BK-P-61N080

1.8

82

0.8

1.2

102

0.52

None

LC42BK-PC-48N048

1.8

69

0.48

1.2

68

0.38

1000

LC42BK-PC-61N080

1.8

82

0.8

1.2

102

0.52

1000

 
Wiring Diagram / Dimension Drawing

 

 

Motor Shaft Output Description

Model (Open-loop)

Model (Closed-loop)

Shaft Diameter D (mm)

Shaft Extension (mm)

Shaft Length (mm

LC42BK-P-48N048

LC42BK-PC-48N048

φ5 or φ6

Flat 0.5×15

24

LC42BK-P-61N080

LC42BK-PC-61N080

φ5 or φ6

Flat 0.5×15

24

 
Electrical Parameters
42 Series Backpack Integrated Machine (Pulse Type)

Category

Minimum Value

Typical Value

Maximum Value

Unit

Input Voltage

24

36

50

V

Drive Current

1.2

A

Input Pulse Frequency

200K

HZ

Protection Functions

Overcurrent, overvoltage, undervoltage, phase loss, large position deviation (closed-loop)

 

Signal Terminal Definition
Terminal Number
Function
Description

1

PUL
Pulse Signal Input

2

DIR
Direction Signal Input

3

ENA
Enable Signal Input

4

NC
No Connection

5

DICOM
Input Signal Common Terminal (5V)

6

DOCOM
Output Common Terminal

7

ALM
Alarm Output

8

Pend
Positioning Complete Output
 
Power Terminal Definition
Terminal Number
Function
Description

1

R485+
R485 Communication Port (not supported by default, customization required)

2

R485-

3

RGND

4

NC
No Connection

5

GND
Power Input Negative Terminal

6

VDC
Power Input Positive Terminal (DC20~50V)
 
DIP Switch
SW1~SW4 Set Microstepping: When set to Default gear, custom microstepping can be set via software.
Microsteps per Revolution
SW1
SW2
SW3
SW4
Default
ON

ON

ON

ON

800

OFF

ON

ON

ON

1600

ON
OFF

ON

ON

3200

OFF
OFF

ON

ON

6400

ON

ON

OFF

ON

12800

OFF

ON

OFF

ON

25600

ON
OFF

OFF

ON

51200

OFF
OFF

OFF

ON

1000

ON

ON

ON

OFF

2000

OFF

ON

ON

OFF

4000

ON
OFF

ON

OFF

5000

OFF
OFF

ON

OFF

8000

ON

ON

OFF

OFF

10000

OFF

ON

OFF

OFF

20000

ON
OFF

OFF

OFF

40000

OFF
OFF

OFF

OFF

SW5: Operating mode, OFF: closed-loop mode, ON: open-loop mode; SW6: default direction, OFF: clockwise, ON: counterclockwise;
 
Main Application Areas

This series of products can be widely used in 3C electronic assembly, medical equipment, printing and packaging, robot joint drive, and other fields, helping customers build compact high-precision motion control systems with efficient, quiet, and intelligent features.

 

Category

Model

Format

Download