Stepper Servo · 17 Years of Expertise

  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
+
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
60 Backpack-type Integrated Motor (RS485)
+
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)
  • 60 Backpack-type Integrated Motor (RS485)

60 Backpack-type Integrated Motor (RS485)

Product Overview

The LC60BK-R integrated stepper driver, with ultra-compact structure and integrated wiring, can greatly save equipment space and reduce wiring complexity.-in high-precision encoder with 16384PPR, paired with closed-loop feedback algorithm, positioning accuracy up to ±0.02°, which effectively eliminate missing steps, suitable for high-precision positioning scenarios.It supports Modbus-RTU protocol, contains 8 segments of internal position table (supporting automatic cycle segments), with functions such as homing, IO position trigger, JOG, alarm reset, etc.; multi-axis control can be achieved via touch screen or controller with485 interface, adapting to different working occasions.

Features

Power supply voltage: DC24V~50V Output peak current: 6.0A Communication interface: RS485 Communication protocol: Modbus RTU With overcurrent, overvoltage, excessive deviation and other alarm protection functions
Product Overview Supporting Products Data Download
 
Product Specifications
Item
Description
Power Supply Voltage
DC24V~50V
Power Supply Power
Single Motor Power ≥ 200W
Output Peak Current
6A
Encoder Resolution
16384ppr (No encoder for open-loop model)
Communication Interface
COM: Serial port, requires special serial cable for communication; RS485: 485 communication port.
Communication Protocol
Modbus RTU
Storage Temperature
-20℃~65℃
Protection Measures
Features overcurrent, overvoltage, large deviation alarm protection functions
Operating Temperature
0℃~50℃
Operating Humidity
40~90%RH (non-condensing)
Vibration Frequency
Less than 0.5G (4.9m/s²) 10Hz~55Hz (non-continuous operation)
Operating Environment
Avoid dust, oil stains, corrosive gases, excessive humidity, and strong vibration; combustible gases and conductive dust are prohibited.
 
Technical Parameters

RS485 Model

Step Angle (°)

Body Length L (mm)

Holding Torque (N.m)

Phase Current (A)

Rotational Inertia (g.cm²)

Motor Weight (kg)

Encoder Line Count (PPR)

LC60BK-R-88N300

1.8

107.7

3.0

4.5

620

1.44

None

LC60BK-R-102N380

1.8

121.7

3.8

5.0

1000

1.48

None

LC60BK-R-112N430

1.8

131.7

4.3

5.8

1200

1.52

None

LC60BK-RC-88N300

1.8

107.7

3.0

4.5

620

1.44

1000

LC60BK-RC-102N380

1.8

121.7

3.8

5.0

1000

1.48

1000

LC60BK-RC-112N430

1.8

131.7

4.3

5.8

1200

1.52

1000

 
Wiring Diagram / Dimension Drawing

 

Motor Shaft Output Description

Model (Open-loop)

Model (Closed-loop)

Shaft Diameter D (mm)

Shaft Extension (mm)

Shaft Length (mm)

LC60BK-R-88N300

LC60BK-RC-88N300

φ8 or φ10

Platform 0.5×15

25 or 31

LC60BK-R-102N380

LC60BK-RC-102N380

φ8 or φ10

Platform 0.5×15

25 or 31

LC60BK-R-112N430

LC60BK-RC-112N430

φ8 or φ10

Platform 0.5×15

25

 
Electrical Parameters
60 Series Backpack Integrated Machine (RS485 Model)

Category

Minimum Value

Typical Value

Maximum Value

Unit

Input Voltage

24

36

50

V

Drive Current

4.6/5/5.6

A

Protection Functions

Overcurrent, overvoltage, undervoltage, phase loss, large position deviation (closed-loop)

 

Signal Terminal Definition and Wiring Instructions
Terminal Number
Function
Description
IO Signal Wiring Diagram

1

R485+
RS485 Communication Port

2

R485-

3

DI1
Input Signal Port 1

4

DI2

Input Signal Port 2

5

DI3
Input Signal Port 3

6

DI4
Input Signal Port 4

7

DICOM
Input Signal Common Terminal (24V)

8

DOCOM
Output Signal Common Terminal (0V)

9

DO1
Output Signal Port 1

10

DO2
Output Signal Port 2
Note: The above diagram shows the default functions of DI/DO ports, which can be modified through PA_033 ~ PA_040 to change the functions of corresponding IO ports.
 
Power Terminals
Terminal Name
Function Description
VDC
DC Power Input Positive Terminal (20~50V)
GND
DC Power Input Negative Terminal
 
DIP Switch
SW1~SW3 Set Station Number: When set to Default gear, a custom station number can be set.
ID
SW1
SW2
SW3
Default
ON

ON

ON

1

OFF

ON

ON

2

ON
OFF

ON

3

OFF
OFF

ON

4

ON

ON

OFF

5

OFF

ON

OFF

6

ON
OFF

OFF

7

OFF
OFF

OFF

SW4~SW5 Set Baud Rate:
Baud Rate
SW4
SW5
4800
ON
ON
9600
OFF
ON
19200
ON

OFF

38400
OFF

OFF

 
Fault Handling
Fault Symptoms
Solutions
Red light steady on or red light flashes once every 3 seconds
Driver overcurrent alarm, check if the motor wires have issues, or unplug the motor wires and power only the driver. If the fault persists, the driver has an internal fault and needs to be returned for repair.
Red light flashes continuously 2 times
Driver overvoltage alarm, check if the input voltage is within the power supply range
Red light flashes continuously 3 times
Driver undervoltage alarm, check if the input voltage is within the power supply range
Red light flashes continuously 4 times
Motor phase loss alarm, the driver motor wire may be disconnected, needs to be returned for repair
Red light flashes continuously 7 times
Position deviation too large alarm, check if the speed is too fast or if the motor is stalled
Red light flashes continuously 8 times
EEPROM storage fault, try initializing parameters and restarting. If the alarm persists, return for repair.
Red light flashes continuously 9 times
Homing timeout alarm, check if PA_055 is 16515.
Red light flashes continuously 10 times
Homing error alarm, check homing parameters and sensor switch, reset alarm and re-home.
Motor enabled normally but cannot trigger operation
Use control word to trigger emergency stop, then check if internal position parameters are set incorrectly, then try to trigger position operation again.
Motor has whining noise
1. Set PA_006 to 0, then restart the driver;
2. Reduce PA_009 and PA_010;
3. Reduce PA_011 and PA_013.
Motor swings back and forth
Check if load inertia is too large, increase deceleration time
 
Main application fields
This series of products can be widely used in 3C electronic assembly, medical equipment, printing and packaging, robot joint drives, and other fields. With features of high efficiency, quiet operation, and intelligence, it helps customers build compact high-precision motion control systems.

 

Category