CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
+
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
CL57-RX Bus Closed-Loop Stepper Driver
+
  • CL57-RX Bus Closed-Loop Stepper Driver
  • CL57-RX Bus Closed-Loop Stepper Driver
  • CL57-RX Bus Closed-Loop Stepper Driver
  • CL57-RX Bus Closed-Loop Stepper Driver
  • CL57-RX Bus Closed-Loop Stepper Driver

CL57-RX Bus Closed-Loop Stepper Driver

Product Overview

The CL57RX is a closed-loop stepper driver. This driver uses an RS485 interface and supports the standard Modbus-RTU protocol. Multi-axis motion control functions can be realized through a touchscreen or a controller with an RS485 communication interface. Users can control up to 31 drivers simultaneously. The driver has 8 internal position tables, supporting functions such as automatic internal position switching, return to zero, position triggering, and JOG.

Features

Voltage input range: DC 20V to 50V Maximum peak current: 5.6A 1000-line encoder Communication interface: RS485 Communication protocol: Modbus RTU Automatic motor parameter tuning function Protection functions including overvoltage, overcurrent, and position deviation alarms
Product Overview Supporting Products Data Download

 

Product Diagram
 
Communication Terminal Description
Pin
Network Cable Color
Signal Definition
Crystal Head Pin Order

1

White Orange
NC

2

Orange
NC

3

White Green
GND

4

Blue
485+

5

White Blue
485-

6

Green
NC

7

White Brown
NC

8

Brown
NC

 

DI/DO Terminal Description
Pin
Definition
Description

1

DI1
Single-ended input port;
Effective operating voltage 24V

2

DI2

3

DI3

4

DI4

5

DI5

6

DI6

7

DICOM
Input port common terminal; compatible with common anode/common cathode wiring

8

DOCOM
Output port common terminal; can only connect to power negative terminal

9

DO1
Single-ended output port

10

DO2
 
Function Terminal Description
Terminal Name
Function Description
GND
DC power input negative terminal
VDC
DC power input positive terminal
A+
Axis 1 motor phase A winding
A-
B+
Axis 1 motor phase B winding
B-
 
Encoder Terminal Description
Terminal Name
Function Description
EA+
Encoder feedback phase A signal
EA-
EB+
Encoder feedback phase B signal
EB-
EVCC
Encoder power positive
EGND
Encoder power negative

 

Communication Network Wiring Diagram

 

DIP Switch
This driver supports the standard Modbus RTU protocol, with 8 data bits, 1 stop bit, no parity check. Baud rate and station number can be set via DIP switches, as shown in the table below:

1. Baud Rate Setting

Baud Rate
9600 (custom)
19200
38400
115200
SW5
ON
OFF
ON
OFF
SW6
ON
ON
OFF
OFF

2. Station Number Setting

Station Number

SW4

SW3

SW2

SW1

1

on

on

on

off

2

on

on

off

on

3

on

on

off

off

4

on

off

on

on

5

on

off

on

off

6

on

off

off

on

7

on

off

off

off

8

off

on

on

on

9

off

on

on

off

10

off

on

off

on

11

off

on

off

off

12

off

off

on

on

13

off

off

on

off

14

off

off

off

on

15

off

off

off

off

3. Open/Closed Loop Setting: SW7: Open/Closed loop control; off=closed loop, on=open loop.

4. Direction Setting: SW8: Motor direction.

 

Fault Handling
Fault Phenomenon
Problem Description
Solution
Red light flashes once
Overcurrent
Driver overcurrent alarm, check if motor wires have issues, or disconnect motor wires and power only the driver. If fault persists, internal driver fault requires factory repair.
Red light flashes four times
Phase loss

 

Red light flashes twice
Overvoltage
Driver overvoltage alarm, check if input voltage is within power supply range.
Red light flashes three times
Undervoltage
Driver undervoltage alarm, check if input voltage is within power supply range.
Red light flashes eight times
EEPROM Fault
Driver Fault
 
Main Application Areas

Suitable for various motion control automation equipment and instruments, such as: electronic processing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, automated assembly equipment, etc.

 

Category

Model

Format