Stepper Servo · 17 Years of Expertise

  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
+
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
+
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver
  • LCDA257X Two-Phase 57 Closed-Loop Stepper Driver

LCDA257X Two-Phase 57 Closed-Loop Stepper Driver

Product Overview

The LCDA257X uses the latest dedicated motor control DSP chip and vector closed-loop control technology to completely overcome the problem of step loss in open-loop stepper motors. At the same time, it significantly improves the motor's high-speed performance, reduces motor heating and vibration, enhances machine processing speed and precision, and lowers machine power consumption. This driver is compatible with two-phase 57-type closed-loop stepper motors, facilitating upgrades from traditional stepper drive solutions and greatly reducing costs.

Features

Voltage input range: DC 20V~50V (recommended above 36V) Maximum peak current: 8A Subdivision range: 400-51200 Pulse form: Pulse + Direction Pulse response frequency: 0~200kHz Logic input current: 10~20mA Insulation resistance: 500M
Product Overview Supporting Products Data Download
 
Main Parameter Description

(1) Electrical Specifications

ParameterLCDA257X
Minimum ValueTypical ValueMaximum ValueUnit
Maximum Peak Current--8A
Input Power Voltage203650VDC
Logic Input Current71020mA
Pulse Frequency--200KHZ

 

Product Diagram
 
Driver Terminal Description

(1) Power Terminal Definition

No.SymbolFunction Definition
1A+
Motor Power Line Terminal
Wiring color see label on motor
2A-
3B+
4B-
5+VDC
DC Power Input Terminal
Recommended DC 36V or above
6GND

(2) Driver Control Terminal Definition

PinSymbolDescription
1
PUL+
Pulse Input Positive
2
PUL-
Pulse Input Negative
3
DIR+
Direction Input Positive
4
DIR-
Direction Input Negative
5
ENA+
Enable Input Positive
6
ENA-
Enable Input Negative
7
ALM+
Alarm Output Positive
8
ALM-
Alarm Output Negative

(3) Driver Encoder Terminal Definition

PinSymbolColorDescription
1
EB+
Yellow
Encoder B Signal Positive
2
EB-
Green
Encoder B Signal Negative
3
EA+
Black
Encoder A Signal Positive
4
EA-
Blue
Encoder A Signal Negative
5
VCC
Red
Encoder +5V Input
6
EGND
White
Encoder Power Ground
 
Microstep Subdivision Setting
Pulse / revSW1SW2SW3SW4
Defaultonononon
800offononon
1600onoffonon
3200offoffonon
6400ononoffon
12800offonoffon
25600onoffoffon
51200offoffoffon
1000onononoff
2000offononoff
4000onoffonoff
5000offoffonoff
8000ononoffoff
10000offonoffoff
20000onoffoffoff
40000offoffoffoff
 

DIP Switch Setting 
The current of this series of drivers is auto-tuned, so manual current setting is not required. The DIP switch functions are as follows:

SW1~SW4: Set driver subdivision (see subdivision table on driver casing, effective after restart);SW5: Set motor direction (ON: forward, OFF: reverse);
SW6: Work mode selection (ON: open loop, OFF: closed loop);SW7: Pulse mode selection (ON: CW/CCW, OFF: PUL+DIR);
SW8: Alarm port logic selection (ON: normally closed, OFF: normally open); 
 
Alarm Handling
Alarm Type
Fault Description
Fault Handling
Flashes once every 5 seconds
Overcurrent Alarm
1. Motor power line short circuit or motor fault;
2. Driver current loop parameter set too high;
3. If no errors found in the above two points, it may be an internal driver fault and needs to be returned for inspection.
Flashes twice every 5 seconds
Overvoltage Alarm
1. Power supply voltage too high or unstable, check if transformer output voltage is normal;
2. Internal driver fault, needs to be returned for inspection.
Flashes three times every 5 secondsor
Flashes seven times every 5 seconds
Encoder Fault
1. Encoder wire is broken or has poor contact.
2. Driver encoder input circuit is damaged.
Overload Alarm
Motor stall or excessive load.
Position Deviation Too Large
1. Motor power line phase sequence reversed, check the sequence according to the label on the motor;
2. Loose, poor contact, or broken motor power line or encoder wire can cause this fault,If there is a spare cable, try replacing the cable;

 

Main Application Areas

Suitable for various motion control automation equipment and instruments, such as: electronic processing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, automated assembly equipment, etc.

 

 