LCDA86X Two-Phase 86 Closed-Loop Stepper Driver
Product Overview
The LCDA86X uses the latest dedicated motor control DSP chip and vector closed-loop control technology, completely overcoming the problem of step loss in open-loop stepper motors. At the same time, it significantly improves the motor's high-speed performance, reduces motor heating, and decreases motor vibration, enhancing machine processing speed and precision while lowering machine energy consumption. This driver combines the dual advantages of stepper and servo motors, and its price is reduced by 50% compared to servo systems on the market, making it the best choice for customers upgrading their stepper solutions.
Features
Main Parameter Description
(1) Electrical Specifications
| Parameter | LCDA86X | |||
| Minimum Value | Typical Value | Maximum Value | Unit | |
| Maximum Peak Current | - | - | 8 | A |
| Input Power Voltage | 24 | 60 | 70 | VDC or VAC |
| Logic Input Current | 7 | 10 | 16 | mA |
| Pulse Frequency | - | 200 | 500 | KHZ |
Product Diagram

Driver Terminal Description
(1) Power Terminal Definition
| Serial Number | Symbol | Function Definition |
| 1 | A+ | Motor Power Line Terminal Wiring color see label on motor |
| 2 | A- | |
| 3 | B+ | |
| 4 | B- | |
| 5 | AC | Power Input Terminal AC: 20V~70V / DC: 30V~100V (no polarity) |
| 6 | AC |
(2) Driver Control Terminal Definition
| Pin | Symbol | Description |
| 1 | PUL+ | Pulse Input Positive |
| 2 | PUL- | Pulse Input Negative |
| 3 | DIR+ | Direction Input Positive |
| 4 | DIR- | Direction Input Negative |
| 5 | ENA+ | Enable Input Positive |
| 6 | ENA- | Enable Input Negative |
| 7 | Pend+ | Position Complete Positive |
| 8 | Pend- | Position Complete Negative |
| 9 | ALM+ | Alarm Output Positive |
| 10 | ALM- | Alarm Output Negative |
(3) Driver Encoder Terminal Definition
| Pin | Symbol | Color | Description |
| 1 | EB+ | Yellow | Encoder B Signal Positive |
| 2 | EB- | Green | Encoder B Signal Negative |
| 3 | EA+ | Black | Encoder A Signal Positive |
| 4 | EA- | Blue | Encoder A Signal Negative |
| 5 | VCC | Red | Encoder +5V Input |
| 6 | EGND | White | Encoder Power Ground |
(4) Driver Communication Terminal Definition
Pin | Symbol | Remarks | ![]() |
1 | NC | No Definition | |
2 | GND | Signal Ground | |
3 | TXD | RS232 Transmit Terminal | |
4 | RXD | RS232 Receive Terminal | |
5 | GND | Signal Ground | |
6 | +5V | Power Positive |
Driver to Computer Communication Cable Connection Method
Color | Computer Side (9-pin Female Connector) |
| Driver Side (6-pin RJ11 Connector) | Color |
Blue | 3 TXD | ----------------- | 4 RXD | Blue |
Green | 2 RXD | ----------------- | 3 TXD | Green |
Orange White Brown | 5 GND | ----------------- | 5 GND 2 GND | Orange White Brown |
Microstep Subdivision Setting
| Pulse / rev | SW1 | SW2 | SW3 | SW4 |
| Default | off | off | off | off |
| 800 | on | off | off | off |
| 1600 | off | on | off | off |
| 3200 | on | on | off | off |
| 6400 | off | off | on | off |
| 12800 | on | off | on | off |
| 25600 | off | on | on | off |
| 51200 | on | on | on | off |
| 1000 | off | off | off | on |
| 2000 | on | off | off | on |
| 4000 | off | on | off | on |
| 5000 | on | on | off | on |
| 8000 | off | off | on | on |
| 10000 | on | off | on | on |
| 20000 | off | on | on | on |
| 40000 | on | on | on | on |
DIP Switch Setting
The current of this series of drivers is auto-tuned, so manual current setting is not required. The DIP switch functions are as follows:
| SW1~SW4: Set driver subdivision (see subdivision table on driver casing for details) | SW5: Set motor direction |
| SW6: Switch driver open-loop/closed-loop working mode |
Alarm Handling
Alarm Type | Fault Description | Fault Handling |
Flashes once every 5 seconds | Overcurrent Alarm | 1. Motor power line short circuit or motor fault; 2. Drive current loop parameter setting is too high; 3. If no errors are found in the above two points, it may be an internal fault of the drive, requiring factory inspection. |
Flashes twice every 5 seconds | Overvoltage Alarm | 1. Power supply voltage is too high or unstable, check if the transformer output voltage is normal; 2. Internal fault of the drive, requiring factory inspection. |
Flashes three times every 5 secondsOr Flashes seven times every 5 seconds | Encoder Fault | 1. Encoder wire is broken or has poor contact. 2. Drive encoder input circuit is damaged. |
Overload Alarm | Motor stall or excessive load. | |
Position Deviation Too Large | 1. Motor power line phase sequence reversed, check the sequence according to the label on the motor; 2. Loose, poor contact, or broken motor power line or encoder wire can cause this fault,If there is a spare cable, try replacing the cable; 3. PA_007 setting is too low causing the alarm, reset the parameter. |
Main Application Areas
Suitable for automation equipment and instruments in various motion control fields, such as: electronic processing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, automated assembly equipment, etc.
Category
Model
Format
Download
Shenzhen Lichuan Electric Co., Ltd.
Technical Support
Engineer Peng:+86-135-3098-8140
Engineer Xie:86-159-0755-7836
Engineer Rao:86-180-2520-1553
Engineer Zuo:86-180-2901-2526
WeChat Public Account
Douyin ID
Official Website Mobile Version
English website: https://www.lichuanservomotor.com/
Sorry,当前栏目暂无内容!
您可以查看其他栏目或返回 首页
Sorry,The current column has no content!
You can view other columns or return Home

WeChat