Stepper Servo · 18 Years of Expertise
Product
CL2-86R Closed-Loop 17-bit Absolute Stepper Driver
Product Overview
The CL2-86R two-phase closed-loop stepper driver is a stepper drive product developed using the latest-generation 32-bit DSP chip, combined with our company’s many years of expertise in motion control. It supports both 17-bit and 23-bit encoders and offers three control interfaces: pulse‑type, RS485 bus, and CANopen bus. This particular model is an RS485‑based closed-loop stepper driver.
Features
Communication Specifications
Communication interface | Communication protocol | Motor flange adapter | Baud rate | Station number | Termination resistor | Check digit |
RS485 | Modbus RTU | 86 | 9600/19200/38400/115200 (SW6–SW7 DIP switch settings) | 0~31 (SW1–SW5 DIP switch settings) | 120 euros (SW8 DIP switch setting) | Invalid verification (default) /odd parity/even parity |
Product illustration

Drive Terminal Description
(1) Main circuit terminal blocks
| Pin | Signal | Explanation |
| 1 | Air conditioning | Drive power supply terminal Power supply range: DC 30 V–110 V / AC 20 V–80 V |
| 2 | Air conditioning |
(2) Motor power cable terminals
| Pin | Signal | Explanation |
| 1 | B- | Motor phase B winding |
| 2 | B+ | |
| 3 | A- | Motor phase A winding |
| 4 | A+ |
(3) Encoder Wiring Terminals
| Pin | Signal | Explanation |
| 1 | EA+/D- | Encoder differential signal negative terminal |
| 2 | EA-/D+ | Encoder differential signal positive terminal |
| 3 | EB+ | If you need to connect an ABZ differential signal encoder Please contact the manufacturer’s technical staff. |
| 4 | EB- | |
| 5 | EZ+ | |
| 6 | EZ- | |
| 7 | E5V | Encoder power supply positive terminal |
| 8 | Ground | Encoder power supply negative terminal |
(4) Control signal terminal block
| Illustration | Pin | Signal | Explanation |
![]()
| 1 | DI0 | 7-channel single-ended DI inputs, 12–24 V, with freely configurable DI functions. |
| 2 | DI1 | ||
| 3 | DI2 | ||
| 4 | DI3 | ||
| 5 | DI4 | ||
| 6 | DI5 | ||
| 7 | DI6 | ||
| 8 | DICOM | DI input common terminal | |
| 9 | DO0 | 3‑channel single-ended DO output, with freely configurable DO functions. | |
| 10 | DO1 | ||
| 11 | DO2 | ||
| 12 | DOCOM | DO output common terminal |
(5) USB port
| Explanation | Explanation |
![]() | Parameters can be configured via a Type-C data cable connected to a computer using debugging software. |
(6) RS485 communication port
| Illustration | Pin | Signal | Explanation |
![]() | 1 | 485+ | 485 communication positive terminal |
| 2 | 485- | 485 communication negative terminal | |
| 3 | Ground | 485 Communication Address | |
| 4 | NC | NC | |
| 5 | Ground | 485 Communication Address | |
| 6 | Ground | 485 Communication Address | |
| 7 | NC | NC | |
| 8 | NC | NC |
(7) DIP switch
| Pin | Signal | Explanation |
| 1 | SW1 | Station number setting; see the table below for details. |
| 2 | SW2 | |
| 3 | SW3 | |
| 4 | SW4 | |
| 5 | SW5 | |
| 6 | SW6 | Baud Rate Setting |
| 7 | SW7 | |
| 8 | SW8 | Termination resistor setting (ON is active, OFF is inactive) |
Communication Station Number Table
| RS485 address | SW1 | SW2 | SW3 | SW4 | SW5 | RS485 address | SW1 | SW2 | SW3 | SW4 | SW5 |
| 1 | on | off | off | off | off | 17 | on | off | off | off | on |
| 2 | off | on | off | off | off | 18 | off | on | off | off | on |
| 3 | on | on | off | off | off | 19 | on | on | off | off | on |
| 4 | off | off | on | off | off | 20 | off | off | on | off | on |
| 5 | on | off | on | off | off | 21 | on | off | on | off | on |
| 6 | off | on | on | off | off | 22 | off | on | on | off | on |
| 7 | on | on | on | off | off | 23 | on | on | on | off | on |
| 8 | off | off | off | on | off | 24 | off | off | off | on | on |
| 9 | on | off | off | on | off | 25 | on | off | off | on | on |
| 10 | off | on | off | on | off | 26 | off | on | off | on | on |
| 11 | on | on | off | on | off | 27 | on | on | off | on | on |
| 12 | off | off | on | on | off | 28 | off | off | on | on | on |
| 13 | on | off | on | on | off | 29 | on | off | on | on | on |
| 14 | off | on | on | on | off | 30 | off | on | on | on | on |
| 15 | on | on | on | on | off | 31 | on | on | on | on | on |
| 16 | off | off | off | off | on |
Baud Rate Setting
| Baud rate | SW6 | SW7 |
115200 | off | off |
38400 | on | off |
19200 | off | on |
9600 | on | on |
Troubleshooting
Fault code | Fault Information | ALM indicator light | Mitigation measures | Reset |
Err1 | Overcurrent or interphase short circuit | Flashes once | Check whether the load is excessive, whether there are any impacts, and whether the motor wiring is shorted. | Power-down reset |
Err2 | Power supply voltage is too high. | Flashes twice | Check the power supply operating range. | Automatic recovery |
Err3 | Power supply voltage too low | Flashes 3 times | Check the power supply operating range. | Automatic recovery |
Err5 | Motor out of tolerance | Flashes 5 times | Check whether the load is excessive and whether the encoder cable is loose. | Power loss, manual reset |
Err6 | 485 Modbus error frame exists | Flashes 6 times | Verify that the 485/USB serial communication parameters are configured correctly. | Power-down reset |
Err7 | Encoder ROM motor information missing | Flashes 7 times | Check whether the encoder ROM correctly stores motor-related parameters. | Power-down reset |
Err8 | Absolute Encoder Battery Warning | Flashes 8 times | Check whether the encoder battery voltage is normal. | Power-down reset |
Err9 | Absolute encoder battery failure | Flashes 9 times | Encoder battery discharged; after replacing the battery, reset P0D.07. | Power-down reset |
Err10 | Encoder Communication Alarm | Flashes 10 times | Check whether the encoder cable is disconnected. | Power-down reset |
Main application areas
Suitable for a wide range of motion-control applications in automation equipment and instruments, such as electronic manufacturing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, and automated assembly systems.
Category
Model
Format
Download
Xinlichuan
Stay in Touch With Us
Shenzhen Lichuan Electric Co., Ltd.
Technical Support
Engineer Xie:+86-159-0755-7836
Engineer Rao:+86-180-2520-1553
Engineer Zuo:+86-135-3098-8140
Engineer Tan:+86-189-3415-0071
Engineer Tang:+86-180-2901-2526
WeChat Public Account
Douyin ID
Official Website Mobile Version
English website: https://www.lichuanservomotor.com
Sorry,当前栏目暂无内容!
您可以查看其他栏目或返回 首页
Sorry,The current column has no content!
You can view other columns or return Home



WeChat