Stepper Servo · 18 Years of Expertise

  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
+
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
+
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver
  • CL286P-ABZ Two-Phase Closed-Loop Stepper Driver

CL286P-ABZ Two-Phase Closed-Loop Stepper Driver

Product Overview

The CL2 series stepper drives are developed using the latest-generation 32-bit DSP chip, combined with our company’s many years of expertise in motion control. They support 1000-line ABZ incremental encoders and are available in three control modes: pulse‑type, RS485 bus, and CANopen bus. This particular model is a pulse‑type drive.

Features

Voltage input range: DC 30 V–110 V, AC 20 V–80 V Maximum peak current: 8 A Compatible motor flange size: 86 Microstep resolution: 0–1,048,576 Pulse type: pulse + direction or dual-pulse Pulse response frequency: 0–250 kHz Communication interface: pulse Equipped with protection functions such as overcurrent, overvoltage, and position deviation alarms.
Product Overview Supporting Products Data Download
 
Product illustration
 
Drive Terminal Description

(1) Main circuit terminal blocks

Pin
Signal 
Explanation

1

Air conditioning 
Drive power supply terminal 
Power supply range: DC 30 V to 110 V or AC 20 V to 80 V 
2
Air conditioning 

(2) Motor power cable terminals

PinSignalExplanation

1

B-
Motor phase B winding 

2

B+ 

3

A-
Motor phase A winding 

4

A+ 

(3) Encoder Wiring Terminals

PinSignalExplanation

1

EA+ 
Encoder A-phase signal positive terminal 

2

EA-
Encoder A-phase signal negative terminal 

3

EB+ 
Encoder B-phase signal positive terminal 

4

EB-
Encoder B-phase signal negative terminal 

5

EZ+ 
Encoder Z-phase signal positive terminal (may be left unconnected if no Z signal is available) 

6

EZ-
Encoder Z-phase signal negative terminal (may be omitted if no Z signal is available) 

7

E5V
Encoder power supply positive terminal 

8

Ground 
Encoder power supply negative terminal 

(4) Control signal terminal block

PinSignalExplanation

1

PUL+ 
Pulse signal input, 250 kHz, 5–24 V differential interface 

2

PUL-

3

DIR+ 
Direction signal input, 250 kHz, 5–24 V differential interface 

4

DIR-

5

DI3
Enable signal 

6

DI4
Alarm Clearance Signal 

7

DICOM 
Enter the common terminal 

8

DO1
Alarm signal 

9

DO2
Positioning signal 

10

DO3
Motor enable flag signal 

11

DOCOM 
Output common terminal 

(5) USB port

ExplanationExplanation
Parameters can be configured via a Type-C data cable connected to a computer using debugging software. 

(6) DIP switch

PinSignalExplanation

1

SW1
Pulse mode, OFF: PIL+DIR, ON: CW+CCW 

2

SW2
Motor direction 

3

SW3
Open-loop/closed-loop switching 

4

SW4
Release signal polarity switching 

5

SW5
Subdivision DIP switch; definitions are shown in the table below. 

6

SW6

7

SW7

8

SW8
 
Subdivision Table
Pulse / revSW5SW6SW7SW8

Default (Through P05.01 setting)

off

off

off

off

800

on

off

off

off

1600

off

on

off

off

3200

on

on

off

off

6400

off

off

on

off

12800

on

off

on

off

25600

off

on

on

off

51200

on

on

on

off

1000

off

off

off

on

2000

on

off

off

on

4000

off

on

off

on

5000

on

on

off

on

8000

off

off

on

on

10000

on

off

on

on

20000

off

on

on

on

40000

on

on

on

on

 
Troubleshooting
Fault code 
Fault Information 
ALM indicator light 
Mitigation measures 
Reset 

Err1

Overcurrent or interphase short circuit

Flashes once

Check whether the load is excessive, whether there are any impacts, and whether the motor wiring is shorted.

Power-down reset

Err2

Power supply voltage is too high.

Flashes twice

Check the power supply operating range.

Automatic recovery

Err3

Power supply voltage too low

Flashes 3 times

Check the power supply operating range.

Automatic recovery

Err5

Motor out of tolerance

Flashes 5 times

Check whether the load is excessive and whether the encoder cable is loose.

Power loss, manual reset

Err6

485 Modbus error frame exists

Flashes 6 times

Verify that the 485/USB serial communication parameters are configured correctly.

Power-down reset

 

Main application areas

Widely used in various precision automation applications, including 3C automation equipment, laser processing systems, engraving machines, dispensing machines, labeling machines, packaging machinery, small CNC devices, textile automation, medical devices, semiconductor testing equipment, vision inspection platforms, and logistics sorting systems.

 

 

Category

Model