Stepper Servo · 17 Years of Expertise

  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
+
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
OL57-R Bus Open-Loop Stepper Driver
+
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver
  • OL57-R Bus Open-Loop Stepper Driver

OL57-R Bus Open-Loop Stepper Driver

Product Overview

The OL57-R stepper driver adopts the new generation 32-bit DSP technology, combined with RS485 bus control function, supports MODBUS-RTU communication protocol, can connect up to 32 axes, and can achieve multi-axis bus synchronous control. The driver features 15 internal position segments and 15 internal speed segments, supports automatic homing, absolute/relative positioning, JOG, and other functions. It can be directly controlled using a touchscreen or a controller with an RS485 interface.

Features

Voltage input range: DC24V to 50V Maximum peak current: 5A Communication interface: RS485 Communication protocol: Modbus RTU Automatic motor parameter tuning function Features overvoltage, overcurrent, and other protection functions
Product Overview Supporting Products Data Download

 

Driver Function Description

Driver Functions

Operating Instructions

Station Number Setting

The driver communication station number is set by five DIP switches SW1-SW5, supporting up to 31 slave stations. In actual use, the driver should be stopped first. Please set the slave address according to the table on the driver panel.

RS485IN/OUT

RS485 communication interface, supports standard Modbus-RTU bus communication protocol.

Baud Rate Setting

The driver communication baud rate is set by two DIP switches SW6~SW7, with a setting range of 9600~115200 in 4 levels. In actual use, the driver should be stopped first. Please set the communication baud rate according to the table on the driver panel. SW8 is the terminal resistor.

Indicator Lights

The driver has two indicator lights: red and green. The green light is the power indicator, which stays on when the driver is powered. The red light is the fault indicator, which stays on when overvoltage or overcurrent faults occur. The red light turns off after the fault is cleared. When a fault occurs, only power cycling and re-enabling can clear the fault.

DI/DO Signal Interface

DI0~DI6 are single-ended input ports, DICOM is the common terminal for inputs; DO0~DO2 are single-ended output ports, DOCOM is the common terminal for outputs. Corresponding command values can be configured as needed to use the functions associated with these command values. Please refer to the driver manual for specific settings.

Motor Interface

A+ and A- connect to the positive and negative terminals of the stepper motor A-phase winding; B+ and B- connect to the positive and negative terminals of the stepper motor B-phase winding. Swapping the + and - terminals of phase A or B can reverse the motor rotation direction.

Power Interface

Powered by DC power supply, recommended operating voltage range is 24V-50VDC, with a recommended operating voltage of 36VDC and power greater than 100W.

Installation Instructions

The driver dimensions are 134×83×33mm, with mounting hole spacing of 128mm. It can be installed horizontally or vertically (vertical installation is recommended). During installation, it should be mounted tightly against a metal cabinet to facilitate heat dissipation.

 

Product Diagram

 

Parameter Settings

The OL57-R driver supports RS485 bus, with 8 DIP switches available to set RS485 station number, communication baud rate, and terminal resistor, as shown in the table below:

 

Station Number Setting
Station NumberSW1SW2SW3SW4SW5Station NumberSW1SW2SW3SW4SW5
Customoffoffoffoffoff16offoffoffoffon
1onoffoffoffoff17onoffoffoffon
2offonoffoffoff18offonoffoffon
3ononoffoffoff19ononoffoffon
4offoffonoffoff20offoffonoffon
5onoffonoffoff21onoffonoffon
6offononoffoff22offononoffon
7onononoffoff23onononoffon
8offoffoffonoff24offoffoffonon
9onoffoffonoff25onoffoffonon
10offonoffonoff26offonoffonon
11ononoffonoff27ononoffonon
12offoffononoff28offoffononon
13onoffononoff29onoffononon
14offonononoff30offonononon
15ononononoff31ononononon

 

Baud Rate Setting
Baud Rate96001920038400115200
SW6onoffonoff
SW7ononoffoff

 

Main Application Areas

Suitable for various motion control automation equipment and instruments, such as electronic processing and inspection, semiconductor packaging, laser cutting and welding, laser typesetting, packaging machinery, engraving machines, marking machines, cutting machines, garment plotters, CNC machine tools, automated assembly equipment, etc.

 

 

Category

Model